Cope-LLG Catalogue 2018

1102 10. Optical instruments and Microscopes Photometers/Polarimeters GENERAL CATALOGUE EDITION 20 E & OE. Polarimeter Polax-2L The Polax-2L (manually-operating meter with digital indicator) is widely used in the sugar, pharmaceutical, chemical, perfume and educational industries. It can accurately measure the angle of rotation (or the value in the international standard sugar scale) with easy operation. 1 ATAGO Specifications Measurement range Angle of rotation: -179.95 to +180° International standard sugar scale: -130 to +130°Z Minimum unit displayed Angle of rotation: 0.05° International standard sugar scale: 0.1°Z Measurement accuracy Angle of rotation: ±0.10° Measurement temperature range: 5 to 40 °C Observation tubes: 1 x 200 mm and 1 x 100 mm Power supply: 100-240 V, 50/60 Hz a.c. Power consumption: 40 VA Dimensions: 43 x 22 x 30 cm Weight: 11.5 kg Type PK Cat. No. Polax-2L 1 9.801 398 1 Polarimeter P8000 series The P8000 with a measurement accuracy of ±0.003° and the P8100 that achieves ±0.002°. Both devices offer the option of a semi-automatic or automatic operation using a peristaltic pump or an autosampler, respectively, and feature all the functions that are important in FDA-regulated sectors. They are suitable for nearly all samples as the parts that come in contact with the sample are chemical- resistant, and for any application, we offer the matching measurement tube in glass or stainless steel. Simple and well- arranged user interface. 2 A.KRÜSS Optronic Specifications Measuring method/Scale: Optical rotation [°], int. sugar scale [°Z], concentration [g/100 ml], spec. rotation customized Measuring range/Resolution: ±90°/0.001° ±259 °Z /0.01 °Z 0 to 99.9 g/100 ml/0.1 g/100 ml Measuring units, angle: °, °Z Measuring time: ±90° 1 s Light source: 1 LED with filter Wave length: 589 nm Max. tube length: 220 mm Permeability: min. 0.1 % (OD3) Calibration: Automatically (menu driven) Display: 5.7"-TFT-Touchscreen, 640 x 480 Pixel Interfaces: 1x USB, 1x RS-232, 1x Ethernet Operating voltage: 110-250 V, 50/60 Hz Temperature range: 0 to 99.9 °C Resolution: 0.1 °C Accuracy: ±0.2 °C Temperature measuring point: Tube Housing: Steel, powder coated Dimensions (W x D x H): 645 x 360 x 200 mm Weight: 28 kg Type Accuracy Description PK Cat. No. P8000 P8100 P8000-T P8100-T P8000-TF P8100-TF P8000-P P8100-P up to ±0.003° up to ±0.002° up to ±0.003° up to ±0.002° up to ±0.003° up to ±0.002° up to ±0.003° up to ±0.002° Without sample temperature control Without sample temperature control With water temperature control With water temperature control With water sample temperature control, flow function With water sample temperature control, flow function With Peltier sample temperature control With Peltier sample temperature control 1 1 1 1 1 1 1 1 6.236 652 6.285 420 6.237 632 6.285 421 6.285 422 6.285 423 6.285 424 6.285 425 2

RkJQdWJsaXNoZXIy MzkwNDcw