Cope-LLG Catalogue 2018

1183 11. Cleanroom, Cleaning and sterilisation Steam sterilisers - Autoclaves/Instruments GENERAL CATALOGUE EDITION 20 E & OE. Benchtop-Autoclaves HMT FA/-MA and -MB series Innovative and versatile autoclave, which combines compact and elegant design with high performance, reliability and safety - Auto dry function: To offer the good dry result - Microprocessor control system: Fully automatic controls from adding water to sterilisation, to drying. - Double water level check device: One for water tank, and one for chamber water level check - Pressure door auto-lock device - Door close indication: All functions stopped and the door light is on, if the door isn't closed completely. - Cycle complete indication: Auto-check each working steps condition. The "COMPLETE" indicator will light up, after correct completion of the batch. - Low water alarm and indication: If there isn't enough water, the "LOW-WATER" indicator will light up, and alarm you. - Pre-heating program: Pre-heating by dry heater, which not only keeps the chamber temperature in balance, but also offers the perfect dry function. - Chamber pressure with double protection: The chamber is protected by a pressure switch and steam pressure safety valve. - Vacuum/Pressure release key: Pushing this key, will cut-off the power supply and exhaust the chamber pressure or release the chamber vacuum, at the same time. - Safety functions such as door lock, over heat protection, water tank level sensor, chamber water level sensor are equipped as standard. - Power supply: 230 V, 50/60 Hz - Inclusive bottom plate HMT 230FA/HMT 260FA - Installed 8 programs and special programs for Liquid sterilisation for your selection - Sterilisation temperature: 105 °C to 135 °C - HMT 230 FA-R and HMT 260 FA-R are certified according to Medical Device Directive as N-class autoclaves HMT 230MA/260MA/300MA - Pre-vacuum function: Offer the excellent sterilisation result. - Dry-vacuum function: To offer the perfect dry result. - 24 Installed programs and special programs for Prion sterilisation, Liquid sterilisation, Bowie-Dick test, Pump test programs for your selection. - Sterilisation temperature: 121 °C to 134 °C - HMT 230MA-R/HMT 260MA-R/HMT 300MA-R are certified according to Medical Device Directive as S-class autoclaves HMT 260MB Klasse-B - Pre-vacuum function: Offer the excellent sterilisation result. - Dry-vacuum function: To offer the perfect dry result. - 10 installed programs: 5 sterilisation programs, 1 customized program for your selection, 3 test programs, drying program - Sterilisation temperature: 105 °C to 135 °C - HMT 260MB is certified according to Medical Device Directive as B-class autoclaves HMC-EUROPE 1 7.980 101 2 4.655 162 3 4.655 164 4 4.655 166 5 6.287 544 1 2 3 4 5 Type Capacity Chamber diam. x depth Width Length Height Rating PK Cat. No. Litres mm mm mm mm kW HMT 230FA HMT 230FA-R* HMT 260FA HMT 260FA-R* HMT 230 MA HMT 230 MA-R* HMT 260 MA HMT 260 MA-R* HMT 300 MA HMT 300 MA-R* HMT 260MB HMT 300MB HMT 300MB with sensor 16 16 24 24 16 16 24 24 40 40 24 40 40 230 x 410 230 x 410 260 x 450 260 x 450 230 x 410 230 x 410 260 x 450 260 x 450 300 x 570 300 x 570 260 x 450 300 x 570 300 x 570 522 522 533 533 522 522 533 533 620 620 553 620 620 594 594 655 655 594 594 655 655 900 900 665 766 766 410 410 442 442 410 410 442 442 489 489 440 489 489 1.9 1.9 2.4 2.4 1.9 1.9 2.4 2.4 3.2 3.2 2.7 2.3 2.3 1 1 1 1 1 1 1 1 1 1 1 1 1 6.237 578 4.655 158 7.980 101 4.655 159 4.655 160 4.655 161 4.655 162 4.655 163 4.655 164 4.655 165 4.655 166 6.287 544 6.287 545 *with recorder

RkJQdWJsaXNoZXIy MzkwNDcw