Cope-LLG Catalogue 2018

1185 11. Cleanroom, Cleaning and sterilisation Steam sterilisers - Autoclaves/Instruments-Accessories GENERAL CATALOGUE EDITION 20 E & OE. Autoclave thermometer Durable bi-metal thermometer with a maximum registering pointer (red), moved up by the temperature measuring pointer, (black), to indicate the highest temperature achieved, and remains there until it is manually reset. - Traceable to NIST Standard - Threaded connection (1/4" NPT), screws directly into in-line processes, can be used to mount thermometer on included stand - Waterproof and pressurised, withstands autoclave cycles and has a removable protective silicone sleeve to prevent moisture from making contact with the dial - Constructed from 304 stainless steel with a glass lens; withstands pressure, high temperatures and rust - Tested and inspected in the USA - Includes a multi-language (English, French, German, Italian, Portuguese, and Spanish) Statement of Accuracy and instructions - Available as an option with an individual Thermometer Calibration Report 1 Bel-Art Products Specifications Measuring range: -20 to +150 °C Probe length: 50 mm Description PK Cat. No. Autoclave thermometer 1 6.287 577 1 Biological Indicators Attest ™ for control of steam autoclaves Biological control involves the use of indicators, which check whether all microorganisms were killed during the sterilisation process. The bio-indicators are unique, as they directly indicate how many microbial spores have actually been killed. Thanks to the reliability and quality of the information, the regular use of a bio-indicator can lead to an improvement in the performance of the sterilization process and thus to better results. Features: - No external laboratory is required for performance evaluation - Easy handling - Reasonable to use after repairs or maintenance of autoclaves Application: - Program 3.5 minutes, holding time at 121 °C or 134 °C - After sterilization, break the vial in order to bring the nutrient solution into contact with the spore strip - Results in 48 hours - Meets EN ISO 11138 standard 2 3M Deutschland Type PK Cat. No. Biological Indicators Attest ™ for steam autoclaves 100 6.089 578 2 Screw Cap GL 45 with temperature probe holder, DURAN ® The DURAN ® temperature probe holder GL 45 consists of a stainless steel holder that is permanently fitted into a blue DURAN ® polypropylene GL 45 cap. The holder will accept the 6.0 mm metal temperature measuring probes that are commonly used in laboratory autoclaves and sterilizers. Applications: - Routine sterilization /autoclave cycles - "Loaded Chamber heat penetration" tests during Performance Qualification (PQ) - Performance tests after autoclave maintenance or repair Features: - Usable with DURAN ® original GL 45 laboratory bottles (1000 ml or less). - The depth of the probe can be adjusted to suit the bottle size - Adjustable ferrule suitable for 6.0 mm diameter probes - Retrace code for product traceability and downloadable certificate - Easy positioning of the sensor in the middle of the bottle 3 4 DURAN Group Type PK Cat. No. Screw Cap GL 45 1 9.072 178 3 4

RkJQdWJsaXNoZXIy MzkwNDcw