Cope-LLG Catalogue 2018

1197 12. Environmental-, soil-, water-, food analysis Sample preparation/Air sampling and analysis GENERAL CATALOGUE EDITION 20 E & OE. Carbon Dioxide Safety Monitor Ax60 The use and storage of CO 2 in laboratories is varied and increasing in popularity including use in CO 2 incubators, glove boxes, in dry ice form for storage, carbonation and many more applications. CO 2 is dangerous, even at relatively low levels and a leak or build up of CO 2 in a confined area could prove potentially lethal for lab personnel. The Ax60 comprises of a wall mounted central display unit, a CO 2 sensor and a CO 2 alarm which can provide an early warning of a CO 2 leak. - No calibration required (unless local regulations state otherwise) - Very long life sensor can last up to 15 years - Up to 4 x CO 2 sensors and 8 x CO 2 alarms can be used per Central Display Unit - Supplied with a relay on each alarm which can be used to trigger ventilation, extraction or a building management system - Easy installation and maintenance can be conducted by the user - Additional (quick connect) CO 2 sensors and alarms available if more than one entrance to the laboratory or more than one risk area - Assists in compliance with Exposure Limit regulations such as EH40 Delivery Includes: 1 x Central Display Unit with 2 relays, 1 x CO 2 Sensor and 1 x CO 2 alarm, complete with universal mains power supply 1 Analox Sensor Technology Specifications Range: 0.1 to 5 % CO 2 Accuracy: ±5% of alarm setpoint Alarm intensity: 88 dbA Monitor Display: 16 digit 2 line LCD in ppm TWA Alarm: 5.000 ppm (0.5%) over 8 hours CO 2 Alarms: 15.000 ppm (1.5%) & 30.000 ppm (3%) Operating Temperature: -5 to 50 °C Central Unit Dimensions: 175 x 110 x 75 mm Sensor & Alarm Dimensions: 72 x 170 x 45 mm IP Rating: IP55 (IP54 Central Display Unit) Warranty: 5 years for electronics and sensor 1 Description PK Cat. No. Ax60 CO 2 Safety Monitor Additional CO 2 Sensor (Max 4 per Central Display Unit) Additional CO 2 Alarm (Max 8 per Central Display Unit) Optional Sensor Protector Kit: Protector bar, splashguard and fixing kit 1 1 1 1 6.284 262 6.284 263 6.284 264 6.284 265 Air sampler, Airport MD8 airborne bacteria sampler AirPort MD8 is a new portable air bacteria sampler for the pharmaceutical and food and beverage industries, hospitals, environmental protection and for industrial safety. AirPort MD8 has the following benefits: - Battery-powered and portable for lab or field use - Battery status display guarantees constant performance during sampling - Ergonomic, smooth design, surfaces can be disinfected - Choice of sampling selection, either by total volume or measurement duration The device can be calibrated on-site. AirPort MD8 uses the gelatin membrane filter method which guarantees reliable and accurate measurement results. 2 Sartorius Specifications Volume flow control: Volume flow can be set to three levels using integral hydrometric manometer: 30 L/min., 40 L/min. and 50 L/min. Fixed sample volumes: 25, 50, 100, 250, 500, 750 and 1000 litres Sample volume can also be adjusted in 5 litre increments Battery: NiMH 16.8 Volt/3800 mAh Running time with a full battery charge: approx. 4 hours Charging time: approx. 4.5 hours if battery flat Noise level: Using gelatin membrane filters, 48 dB(A) Weight: 2.5 kg Dimensions (L x W x H): 300 x 135 x 165 mm Filter size: 80 mm dia., area 38.5 cm² Type PK Cat. No. AirPort MD8 1 9.841 605 2

RkJQdWJsaXNoZXIy MzkwNDcw