1243 12. Environmental-, soil-, water-, food analysis Sample analysis/Turbidity GENERAL CATALOGUE EDITION 20 E & OE. Turbidity meter TN100 The microprocessor-based waterproof Infra-Red Turbidity meter TN100 is easy-to-use and meets all rigor of rugged field applications. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units). - IP67 Waterproof and Dustproof, easy cleaning and maintenance - Automatic Push-Button Calibration (4 points) for unprecedented full-range accuracy - Power-saving feature allows over 1200 measurements - Large Easy-to-Read Display for optimum viewing of measurements with user-friendly message codes for easy troubleshooting - Meets Performance Criteria as specified by ISO 7027 (DIN EN 27027) method Scope of supply: Turbidity meter with 4 calibration standards, 3 empty cuvettes, sturdy carrying case, batteries and instruction manual 1 Eutech Specifications Turbidity range: 0 to 1000 NTU Resolution: 0.01 NTU (0 to 19.9 NTU) 0.1 NTU (20.0 to 99.9 NTU) 1 NTU (100 to 1000 NTU) Accuracy: ±2 % of reading ±1 LSD ( 0 to 500 NTU) ±3 % of reading ±1 LSD (501 to 1000 NTU) Repeatability: ±1 % of reading or ±0.01 NTU Calibration Points: 4 points (automatic) Response Time: < 6 seconds for full step change Calibration Standards: 0.02 NTU; 20.0 NTU; 100 NTU; 800 NTU Light Source: Infrared-emitting diode (850 nm) Light Source Life: > 1.000.000 tests Power supply: 4 x 1.4 V batteries, > 200 h Type PK Cat. No. Turbidity meter TN100 1 6.205 327 1 6.205 327 Turbidity meters Turb ® 430 The turbidity meters Turb ® 430 IR acc. to DIN ISO 27027 and Turb ® 430 T acc. to US EPA 180.1 meet the requirements of the nephelometric measurement at 90° stray light for drinking water with highest precision, especially in the range < 1 NTU. The measuring range comprises 0-1100 NTU/FNU with automatic measuring range switching and is therefore suitable for water analysis as well as quality control, such as gasoline, cell cultures, as well as in the food and beverage industries. The measurement and automatic 3-point calibration runs self-explanatory and menu-controlled. The calibration takes place via an AMCO Clear ® standard set (0.02-10-1000 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata. The quality assurance of the measured results is supported by calibration interval setting with documentation. Scope of delivery: Turb ® 430 IR/Turb ® 430 T: Turbidity meter with calibration set 0.02-10.0-100 NTU Turb ® 430 IR/SET/Turb ® 430 T/SET: Turbidity meter in case with table insert, calibration set 0.02-10.0-100 NTU, PC software LSdata, accessories 2 WTW ® Specifications Measuring range: NTU 0 to 1100 FNU 0 to 1100 Resolution: 0.01 in the range 0.00 to 9.99 0.1 in the range 10 to 99.90 1 in the range 100 to 1100 Accuracy: ±0.01 NTU or ±2 % of measured value Reproducibility: 0.01 NTU or < 0.5% vof measured value Cell size: 28 x 60 mm, 20 ml sample volume Power supply: 4 x AA batteries for approx. 3000 measurements Type Description PK Cat. No. Turb ® 430 IR Turb ® 430 T Turb ® 430 IR/SET Turb ® 430 T/SET with infra red LED with tungsten lamp with infrared LED with tungsten lamp 1 1 1 1 6.223 101 7.650 036 9.923 603 9.923 604 2 9.923 604

RkJQdWJsaXNoZXIy MzkwNDcw