Cope-LLG Catalogue 2018

1312 13. Life Sciences Proteomics/Blotting GENERAL CATALOGUE EDITION 20 E & OE. Semi Dry Blotters These Semi Dry Blotters offer rapid transfer times for DNA, RNA and protein blotting; typically 15 to 30 minutes. All units can be used for all types of blotting: western, southern and northern via uncomplicated buffer and set up procedures and are compatible with gel thicknesses from 0.25 up to 10mm without the need for additional equipment. Each unit is compatible with their respective omniPAGE vertical gel system. Semi Dry Blotting has the added benefit of economic transfers due to very low buffer volumes - typically only a few millilitres of buffer are required per transfer. These Semi-Dry Blotters utilise a screw down lid, which secures the blot sandwich and allows complete control of pressure ensuring even transfer. The electrodes, comprising platinum coated anode and stainless steel cathode, will exhibit practically no corrosion and so provide many years of trouble free use. Uniform heat dispersion across the blot sandwich ensures stable transfer times and no heat induced sample loss or transfer distortions. Being translucent, it allows viewing of the blot sandwich to ensure correct positioning and transfer is occurring correctly. Electrode plates are fully separated to prevent arching or damage. Cleaver Scientific 1 1 Type Description Dimensions (W x D x H) Capacity Buffer Qty. Blots Dimensions blots PK Cat. No. mm ml cm SD10 SD20 Mini, 10 x 10 cm Maxi, 20 x 20 cm 160 x 160 x 70 260 x 260 x 70 5 20 1 1 2 4 8 x 8,5 16 x 17,5 16 x 8,5 8 x 8,5 1 1 9.584 753 6.229 381 Blotting paper Recommended for blotting techniques with gels, like Southern, Northern and Western Blots, even Semidry-Blots of proteins - Made from ultrapure cotton linters and cellulose, entirely without additives to ensure that no contamination will occur during the transfer steps - Tested specifically for chromatographic and blotting techniques to ensure high and uniform capillary actions - High wet strength for safe handling Further sizes on request. 2 Hahnemühle Description Width Length Thickness Weight PK Cat. No. mm mm mm g / m² medium absorbency medium absorbency medium absorbency high absorbency 570 600 600 600 460 580 580 580 0.35 0.35 0.90 1.50 192 192 320 570 100 100 50 25 4.006 154 4.006 155 4.006 156 4.006 157 2 Gel blotting paper GB 003, GB 005. High purity. Very absorbent. Easy to use. Suitable for all protein and nucleic acid blotting techniques. 3 GE Healthcare Type Width Length Wall thickness PK Cat. No. mm mm mm GB 003 GB 003 GB 003 GB 005 GB 005 200 600 600 200 580 200 300 580 200 580 0.8 0.8 0.8 1.2 1.2 100 25 50 25 25 9.057 077 9.057 067 9.057 078 9.057 079 9.057 075 3 9.584 753

RkJQdWJsaXNoZXIy MzkwNDcw