Cope-LLG Catalogue 2018

1314 13. Life Sciences Proteomics/Blotting-Blot Imaging GENERAL CATALOGUE EDITION 20 E & OE. X-Ray cassettes Standard design with lead lining and snap fit lid. - easy to open, easy to close with gentle pressure. - firm, consistent support for films through special shaping: base pre-formed with convex profile. - flexible, pure aluminium base (Absorption 1.2mm Al-value) flim processed in frames - Aluminium base coated in impact-resistant paint - Anodised aluminium frame - Elastic foam for film protection - Specifically designed for audioradiography at 70 °C Use our reinforcement films in the blue sensitivity range with these X-Ray cassettes. 1 Format PK Cat. No. mm 180 240 200 356 x x x x 240 300 400 432 1 1 1 1 9.106 580 9.106 581 9.106 582 9.106 583 1 Reinforcement films for X-Ray cassettes Reinforcement films Universal B 1 CaWo 4 , blue. Format PK Cat. No. mm 180 240 200 356 x x x x 240 300 400 432 2 2 2 2 9.106 570 9.106 571 9.106 572 9.106 574 2 Type PK Cat. No. CELVIN ® S 160+ CELVIN ® S 320+ CELVIN ® S 420 CELVIN ® S 420 FL CELVIN ® S 830 1 1 1 1 1 6.268 396 6.268 397 6.268 395 6.287 656 6.268 394 2 Chemiluminescence Imager CELVIN ® biostep GmbH The innovative, small and compact Celvin ® S Chemiluminescence Imager enables a high photon yield due to small distance of the sample to the detecting CCD chip which leads to short exposure times. - Resolution and sensitivity can individually be adjusted - Electromagnetic locking mechanism ensures safety during measurements - Sensitive cooled 16 Bit CCD proprietary camera - One-hand operation by touch-screen with status information - Small, compact and space-saving system - Storage of the acquisition settings in individual, application-dependent methods - Acquisition of image series for signal reinforcements - Comfortable and automatic handling via user-friendly software for Western Blots and 1D Gels biostep Celvin ® S 160+ : Resolution 1.6 MPixel: 1536(H) x 1024(V), Integration time: from 0.5 sec up to 24 hrs, Maximum field of view 12 x 8 cm. biostep Celvin ® S 320+ : Ultra-sensitive system, Resolution 3.2 Mpixel: 2184(H) x 1472(V), Integration time: from 0.5 sec up to 24 hrs, Maximum field of view 13 x 9 cm. biostep Celvin ® S 420 : Sensitive system, Resolution 4.2 Mpixel: 2048(H) x 2048(V), Integration time: from 0.03 sec up to 24 hrs, Maximum field of view 14 x 14 cm. biostep Celvin ® S 420 FL : Fluorescence system, Sensitive system, Resolution 4.2 Mpixel, excitation with LEDs red, green, blue and 365 nm, 4 emission filters 490, 550, 600 and 680 nm, Maximum field of view 14 x 14 cm. biostep Celvin ® S 830 : Sensitive system, Resolution 8.3 Mpixel: 3366(H) x 2544(V), Integration time: from 0.5 sec up to 24 hrs, Maximum field of view 14 x 12 cm. Features: - Sensitive fixed focal lens for chemiluminescence - Air-cooled double peltier technique, T -40 °C - Compact dark hood - Dimmable white top-light (intensity 10 - 100 %) for colorimetrically-stained markers - Binning 1x1, 2x2, 3x3, 4x4, 5x5, 6x6 - Weight: 10 kg - Dimensions (W x D x H): 24 x 36 x 42 cm - Minimum requirements for PC: Processor Intel i3, 3 GHz, 2 GB RAM, Win 7/8, 2 free USB 2.0 ports

RkJQdWJsaXNoZXIy MzkwNDcw