Cope-LLG Catalogue 2018

1374 13. Life Sciences Microbiology/Filtration GENERAL CATALOGUE EDITION 20 E & OE. LLG-Microbiological Monitors and Analytical Funnels LLG-Microbiological Monitors and Analytical funnels provide a ready-to-use solution for the filtration of liquid samples using a manifold. No need for flaming or sterilization, reduces the testing time up to 70 %. These 100 ml units are suited for monitoring contaminants in all types of samples, from raw materials to finished products. In the case of Microbiological Monitors the nitrocellulose membrane is fixed to the unit. The filtration unit easily converts to a Petri dish, which can be labeled and incubated for further analysis. When using analytical funnels the nitrocellulose membrane can be removed and transferred to a Petri dish for further analysis. Adapter for use with a manifold is included. LLG-Analytical funnels, sterile 1 Capacity Diam. Pore size Colour Filter / Grid PK Cat. No. ml mm µm 100 100 100 100 100 100 47 47 47 47 47 47 0.45 0.45 0.20 0.20 0.45 0.45 white / black white / black* white / black white / black* black / white black / white* 50 50 50 50 50 50 6.268 176 6.268 177 6.268 178 6.268 181 6.268 179 6.268 180 *single packed 1 LLG-Microbiological Monitors, sterile 2 Capacity Diam. Pore size Colour Filter / Grid PK Cat. No. ml mm µm 100 100 100 100 100 100 100 100 100 47 47 47 47 47 56 56 56 56 0.20 0.45 0.45 0.45 0.80 0.20 0.45 0.45 0.80 white / black white / black white / black* black / white black / white white / black white / black black / white black / white 50 50 50 50 50 50 50 50 50 6.268 190 6.268 186 6.268 187 6.268 188 6.268 189 6.268 185 6.268 182 6.268 183 6.268 184 *single packed 2 LLG-vacuum manifold, stainless steel Multi-branch vacuum manifolds ideal for microbiological monitors and analytical funnels filtration using a perforated no. 8 stopper. These space-saving 3- or 6-place manifolds have specifically been designed for operators working in laminar flow hoods. Each manifold position is equipped with a large and easy to operate 2-way valve. The tubing to the vacuum source can be connected to either side of the manifold. A unique system has been incorporated to ensure the stability of the manifold on non-flat working areas. The stainless steel base can be autoclaved; valves and adaptor tubing cannot be autoclaved. The system includes stainless steel manifold with valves, no. 8 stopper and tubing adaptor for microbiological monitors and analytical funnels. Adapter suitable for Microbiological Monitors and Analytical Funnels with a drain diameter of 95 mm e.g. LLG-Monitors and LLG-Analytical funnels. 3 4 Description PK Cat. No. 3-place stainless steel manifold 6-place stainless steel manifold 1 1 6.269 118 6.269 119 3 6.269 118 4 More extraction devices please see chapter 6.

RkJQdWJsaXNoZXIy MzkwNDcw