Cope-LLG Catalogue 2018

1 2 1463 14. Chromatography Gas chromatography/Gas generators GENERAL CATALOGUE EDITION 20 E & OE. Hydrogen Generators for GC combustion detector applications and GC and GC/MS carrier gas applications The H-MD generators ideally supply GC and GC/MS carrier gas, in addition to all known combustion detectors that are routinely used in today's laboratory workflows. Utilising field proven PEM cell technology, hydrogen is produced on demand from deionised water and electricity, at low pressure and with minimal stored volume. - Eliminate dangerous hydrogen cylinders from the work place - Simple to install and operate - Compact, reliable with minimal maintenance - Produces a continuous supply of 99.9995% pure hydrogen at up to 6.9 bar - (H-MD) Produces a continuous supply of 99.99995% pure hydrogen up to 1.100ml/min and 6.9 bar - 2 year warranty for the cell - Optional automatic water fill and remote networking capability - Type H for high purity, Type H-MD for ultra-high purity hydrogen 1 Parker Hannifin Specifications Ambient Temperature Range: 5 - 40 °C Water Supply Pressure*: 0.1 bar g Water Supply Flow Rate*: 1 L/min Water Quality: ASTM II, >1 MO, <1 µs, filtered to <100 µm Supply Voltage Range: 90 - 264V 50/60 Hz Type Flow rate Flow rate Dimensions (W x D x H) Purity Delivery Pressure Weight PK Cat. No. L / min. L / week mm % bar g kg 20H* 40H* 60H* 20H-MD* 40H-MD* 60H-MD* 110H-MD 0.16 0.25 0.50 0.16 0.25 0.50 1.10 1.25 2.00 4.00 1.69 2.41 4.82 10.60 342 x 437 x 456 342 x 437 x 456 342 x 437 x 456 342 x 470 x 456 342 x 470 x 456 342 x 470 x 456 342 x 470 x 456 >99.9995 >99.9995 > 99.9995 >99.99995 >99.99995 >99.99995 >99.99995 0.3 - 6.89 0.3 - 6.89 0.3 - 6.89 0.69 - 6.89 0.69 - 6.89 0.69 - 6.89 0.69 - 6.89 19.0 19.0 19.0 20.5 20.5 20.5 23.6 1 1 1 1 1 1 1 9.870 301 9.870 302 9.870 303 9.870 311 9.870 312 9.870 313 9.870 314 Note: For auto water fill option add suffix AWF ie 20H-AWF or 20H-MD-AWF *With optional AWF Zero Air Generators for GC combustion detector applications The UHP-ZA zero air generators produce a continuous stream of organic impurity free air. The stackable system forms an innovative, modular FID gas station suitable for all known GC combustion detectors such as FID, FPD and NPD. - Ultra high purity, organic free, air for GC combustion detectors - Increase resolution and detection limits of analysis - Compact, reliable with minimal operator attention and maintenance - Eliminate inconvenient and potentially dangerous air cylinders - Payback period typically less than 24 months - Models available to supply up to 75 FID's 2 Parker Hannifin Specifications Ambient Temperature Range: 5 - 40 °C Organic Impurity: < 0.1 ppm Inlet Air Quality: Clean dry compressed air ISO8573-1:2001 Class 3.2.1 Supply Voltage Range: 207 - 253 V 50/60 Hz Type Flow rate Air Inlet Dimensions (W x D x H) Delivery Pressure Weight PK Cat. No. L / min. L/min mm bar g kg UHP-10ZA-S UHP-35ZA-S UHP-50ZA-S UHP-75ZA-S UHP-150ZA-S UHP-200ZA-S UHP-300ZA-S 1.00 3.50 5.00 7.50 15.00 20.00 30.00 1.2 42.0 6.0 9.0 18.0 24.0 35.0 340 x 425 x 325 340 x 425 x 325 340 x 425 x 325 340 x 425 x 325 340 x 425 x 325 340 x 425 x 325 340 x 425 x 325 4 - 10 4 - 10 4 - 10 4 - 10 4 - 10 4 - 10 4 - 10 10.2 14.2 14.2 14.2 15.2 15.2 15.2 1 1 1 1 1 1 1 9.870 331 9.870 332 9.870 333 9.870 334 9.870 335 9.870 336 9.870 337 Note: Add suffix E' for 207-253V 50/60Hz ie. UHP-10ZA-S-E

RkJQdWJsaXNoZXIy MzkwNDcw