Cope-LLG Catalogue 2018
413 3. Analytical measurement and testing Density determination/Viscosimeter GENERAL CATALOGUE EDITION 20 E & OE. Viscometers, glass, kinematic, Ubbelohde To ISO/DIS 3105. DIN 51562. BS 188. NF T 60 to 100. Without documentation of the constants. For manual and automatic relative measurements. 1 SI Analytics Type Capillary Constant PK Cat. No. K 53001 53003 53010 53013 53020 53023 53030 53033 53040 0a 0c I Ic II IIc III IIIc IV 0.005 0.003 0.01 0,03 0.1 0.3 1 3 10 1 1 1 1 1 1 1 1 1 9.268 301 9.268 303 9.268 310 9.268 313 9.268 320 9.268 323 9.268 330 9.268 333 9.268 340 1 Viscometers Ubbelohde, glass, kinematic ISO 3105, DIN 51562, NF T60-107 For manual (type 501 ..) or automatic (type 532 ..) measurements. Constants documented in manufacturer's certificate. 2 SI Analytics Type Capillary i.d. Measuring range Capillary Constant PK Cat. No. mm mm 2 / sec K 501 00 501 03 501 01 501 10 501 13 501 11 501 20 501 23 501 21 501 30 501 33 501 31 501 40 532 00 532 03 532 01 532 10 532 13 532 11 532 20 532 23 532 21 532 30 532 31 532 33 532 40 0.36 0.47 0.53 0.63 0.84 0.95 1.13 1.50 1.69 2.01 2.65 3.00 3.60 0.36 0.47 0.53 0.63 0.84 0.95 1.13 1.50 1.69 2.01 3.00 2.65 3.60 0.2 - 1 0 - 3 0.8 - 5 1.2 - 10 3 - 30 5 - 50 10 - 100 30 - 300 50 - 500 100 - 1000 300 - 3000 500 - 5000 1000 - 10000 0.3 - 1 0.5 - 3 0.8 - 5 1.2 - 10 3 - 30 5 - 50 10 - 100 30 - 300 50 - 500 100 - 1000 500 - 5000 300 - 3000 1000 - 10000 0 0c 0a I Ic Ia II IIc IIa III IIIc IIIa IV 0 0c 0a I Ic Ia II IIc IIa III IIIa IIIc IV 0.001 0.003 0.005 0.01 0.03 0.05 0.1 0.3 0.5 1 3 5 10 0.001 0.003 0.005 0.01 0.03 0.05 0.1 0.3 0.5 1 5 3 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 9.268 100 9.268 103 9.268 101 9.268 110 9.268 113 9.268 111 9.268 120 9.268 123 9.268 121 9.268 130 9.268 133 9.268 131 9.268 140 7.023 176 9.268 203 9.268 201 9.268 210 9.268 213 7.023 177 9.268 220 9.268 223 7.023 178 9.268 230 7.023 179 9.268 233 9.268 240 2 Viscometer holders Type 05392. VA steel. Suitable for all Ubbelohde viscometers without TC sensors. For manual and automatic measurements. Holds the viscometer perpendicularly. Accuracy <1°. Protects the viscometer from damage. 3 SI Analytics Type PK Cat. No. 05392 1 9.268 790 3 Viscometer heating jacket With support plate for Ubbelohde and capillary viscometers. Can be thermoregulated in mantles in the temperature range 0 to 180 °C. 4 SI Analytics Type PK Cat. No. Viscometer heating jacket 1 9.269 420 4
Made with FlippingBook
RkJQdWJsaXNoZXIy MzkwNDcw