427 3. Analytical measurement and testing Analytical instruments and systems/Melting point determination GENERAL CATALOGUE EDITION 20 E & OE. Melting Point Apparatus, advanced, SMP30 - Maximum temperature 400 °C - Patented head up display - Integrated cooling 350 °C to 50 °C in 12 minutes - Large easy to read user friendly interface The SMP30 can take three samples simultaneously within the optimised heating block. To allow maximum flexibility a plateau facility is included with variable ramp rate between 0.5 and 10 °C in 0.1 °C increments. The tubes are illuminated with bright white LED's to give the clearest view of the samples during the melt. The block has been designed for easy access for cleaning. To allow the most comfortable viewing angle the SMP30 features a two stage head adjustment. The SMP30 features the patent pending head up display, this unique feature displays a floating image of the block temperature, visible through the eyepiece, in front of the tubes. An accessory printer is available separately to produce a written record of the melt. 1 2 Stuart Specifications No of samples: 3 Temperature range: Ambient to 400 °C Temperature resolution: 0.1 °C Display: 40 x 4 segment LCD Ramp rates: 0.5 to 10 °C in 0.1 °C increments Memory: 8 results per tube Date/time display: Yes Cool down time: 350 to 50 °C (~12 mins) Heat up time: 50 to 350 °C (~ 6 mins) Supply requirements: 120V/230V 50Hz Language variants: English, German, French, Italian Temperature unit: °C 1 2 Type PK Cat. No. Melting point apparatus, complete with pack of 100 melting point tubes, closed at one end. Melting point tubes, closed at one end. Accessory printer with power supply 1 100 1 9.950 188 6.803 067 9.950 399 Melting Point Meter M5000 For powdery substances with a melting point up to 400 °C. A fan cooling allows fast measurements in every range of temperature. The display provides a clearly-arranged readout of all important measuring data. - Fully automatic measuring instrument - Digital temperature control via LCD-display - Sealed keyboard for easy cleaning - Alarm function when reaching the melting point - Digital display of all important data - Display in German and English - Automatic quick cooling by integrated fan - Inclusive instrument protective cover and 100 melting point tubes - With RS-232 interface for printer CBM910 3 A.KRÜSS Optronic Specifications Measuring range: 25 - 400 °C Resolution: 0.1°C Accuracy: ±0.3°C (25 - 200 °C) ±0.5°C (200 - 400 °C) Reproducibility: ±0.2 °C Safety class: IP 20 Preheating rate: up to 300 °C approx. 4.0min up to 400 °C approx. 7.5min Heating rate during measurement: 1 °C min -1 Capillary-Ø: 1.4 mm Capillary intake: 1 Power supply: 90 - 264V Dimensions (W x D x H): 230 x 210 x 110 mm Weight: approx. 1.8 kg Type PK Cat. No. Melting Point Meter M5000 1 6.264 452 3

RkJQdWJsaXNoZXIy MzkwNDcw