Cope-LLG Catalogue 2018

778 7. Heating and cooling technology Temperature regulators/Heating-Thermostats GENERAL CATALOGUE EDITION 20 E & OE. Thermostatic controllers Optima ™ TX150/TXF200 Combine with a plastic or stainless steel tank or with an accessory T-clamp for independent use. The two advanced heating circulators feature a modern, icon driven programming interface and full colour display. Cooling/heating range: -15 °C to +150 °C* (TX150) and -15 °C to +200 °C* (TXF200). *For using at or below room temperature you need additional flow coolers C1G (9.920 765) or C2G (9.920 766). Features: Visual and audible alarm, timer, 5 point recalibration, adjustable over temperature cut-out, pump, external probe, progammable, relay, menu system, program storage, USB port. T Clamp: For attaching the thermostats to any vertical sided tank with a maximum wall thickness of 35 mm for rectangular tanks, 30 mm for circular tanks (300 mm diameter), and a capacity of up to 50L. Models with clamps available on request. 1 Grant Specifications Temperature range with stainless steel tank TX150: -15 °C to 150 °C* TXF200: -15 °C to 200 °C* Stability/Uniformity (DIN 12876) at 70 °C: ±0.01 °C/±0.05 °C Setting resolution: 0.1 °C (0.01 °C with Labwise) Display: QVGA TFT Timer: 1 min to 99 hrs 59 mins No. of pre-set temperatures: 3 Recalibration points: 5 Heating power (230V): 1.9kW Power supply (230V/50-60Hz): 2.0kW Interface: USB and RS232 Pump max. pressure TX150: 310 mbar TXF200: 530 mbar Flow rate max. TX150: 18l/min TXF200: 22l/min (adjustable) 1 Type Programmable PK Cat. No. TX150 TXF200 T clamp remote via PC/labtop, 1 program / 30 segments direct via user interface or remote via PC/labtop, 10 programs / 100 segments - 1 1 1 9.699 632 9.699 633 9.699 634 Accessories for water baths Optima ™ series Drain syphon SY1 : For the rapid draining of baths. Heat exchange coil CW5: For use with precision and general purpose stirred baths. Temperature range 2 °C above coolant temperature. Coil diameter/l mm 77/55, pipe bore inlet/outlet 7mm. PP spheres PS20: Between operating temperatures 60 °C and 100 °C and below room temperature a lid or layers of polypropylene spheres can be used. Above 100 °C a lid must be used. C1G refrigerated cooler: For use with all stainless steel Optima ™ baths ranging from 0 °C to +40 °C. For 220 - 240 V 50 Hz single phase supplies. C2G refrigerated cooler: For use with all stainless steel Optima ™ baths ranging from -20 °C to +40 °C. A bath lid must be used at temperatures below 0 °C, in order to achieve optimum performance. For 220 - 240 V 50 Hz single phase supplies. 2 Grant Type PK Cat. No. PP spheres PS20 Drain syphon SY1 Heat exchange coil CW5 Refrigerated cooler C1G Refrigerated cooler C2G 300 1 1 1 1 6.239 419 9.699 096 9.920 764 9.920 765 9.920 766 2 6.239 419

RkJQdWJsaXNoZXIy MzkwNDcw