Cope-LLG Catalogue 2018

804 7. Heating and cooling technology Temperature regulators/Dynamic Temperature Control Systems GENERAL CATALOGUE EDITION 20 E & OE. Temperature control systems, Unistat ® to -55 °C Unistats are predestined for applications in process and chemical engineering, such as temperature control of reactors, autoclaves, miniplant/pilot systems, reactor blocks and calorimeters. Unistat temperature control systems with their unique thermodynamics provide highly accurate and reproducible results, guaranteeing the shortest heating and cooling times and a wide temperature range without fluid change. Environmentally and economically Unistats stand out, offering natural refrigerants and an efficient energy management system for reduced operating costs. 1 Huber Heating capacity Unistat ® tango ® / tango ® wl/405/405w/410w: 1.5/3.0kW Unistat ® 410: 3.0kW Unistat ® 425/425w: 2.0kW Unistat ® 430/430w: 4.0kW Unistat ® 510/510w: 6.0kW 1 Type Pump max. Cooling capacity kW at 250/200/100/0/-20/-40 °C Working Temp. range PK Cat. No. l/min/bar °C Unistat ® tango ® Unistat ® tango ® wl Unistat ® 405 Unistat ® 405w Unistat ® 410w Unistat ® 425 Unistat ® 425w Unistat ® 430 Unistat ® 430w Unistat ® 510 Unistat ® 510w 55 / 0.9* 55 / 0.9* 55 / 0.9* 55 / 0.9* 55 / 0.9* 105 / 1.5** 105 / 1.5** 90 / 1.7** 90 / 1.7** 105 / 1.5** 105 / 1.5** 0.7 / 0.7 / 0.7 / 0.7 / 0.4 / 0.06 0.7 / 0.7 / 0.7 / 0.7 / 0.4 / 0.06 1.0 / 1.0 / 1.0 / 1.0 / 0.6 / 0.15 1.3 / 1.3 / 1.3 / 1.3 / 0.7 / 0.15 1.7 / 2.5 / 2.5 / 1.5 / 0.8 / 0.2 2.0 / 2.0 / 2.0 / 2.5 / 1.8 / 0.2 2.8 / 2.8 / 2.8 / 2.5 / 1.9 / 0.2 3.5 / 3.5 / 3.5 / 3.5 / 2.2 / 0.3 3.5 / 3.5 / 3.5 / 3.5 / 2.2 / 0.3 5.3 / 5.3 / 5.3 / 5.3 / 2.8 / 0.9 5.3 / 5.3 / 5.3 / 5.3 / 2.8 / 0.9 -45 ... +250 -45 ... +250 -45 ... +250 -45 ... +250 -45 ... +250 -40 ... +250 -40 ... +250 -40 ... +250 -40 ... +250 -50 ... +250 -50 ... +250 1 1 1 1 1 1 1 1 1 1 1 9.859 101 9.859 102 9.859 108 9.859 107 9.859 126 9.859 116 9.859 117 9.859 118 9.859 119 9.857 299 9.859 120 *Integrated pressure control VPC **VPC pressure control via optional bypass Temperature control systems, Unistat ® to -85 °C 2 Huber Heating capacity Unistat ® 705/705w: 1.5/3.0kW Unistat ® 815/815w: 2.0kW Safety class: FL, III Supply requirements: 230/400V 50Hz (705/705w) 400V 50Hz (815/815w) Dimensions (W x D x H) Unistat ® 705/705w: 425 x 400 x 720 mm Unistat ® 815/815w: 460 x 604 x 1465 mm 2 Type Pump max. Cooling capacity kW at 250/200/100 °C Cooling capacity kW at 0/-20/-40/-60/-80 °C Working Temp. range PK Cat. No. l/min/bar °C Unistat ® 705 Unistat ® 705w Unistat ® 815 Unistat ® 815w 55 / 0.9 55 / 0.9 40 / 0.9 40 / 0.9 0.6 / 0.6 / 0.6 0.6 / 0.6 / 0.6 1.3 / 1.3 / 1.3 1.5 / 1.5 / 1.5 0.65 / 0.6 / 0.6 / 0.3 / -- 0.65 / 0.6 / 0.6 / 0.3 / -- 1.5 / 1.5 / 1.4 / 1.2 / 0.2 1.5 / 1.5 / 1.4 / 1.2 / 0.2 -75 ... +250 -75 ... +250 -85 ... +250 -85 ... +250 1 1 1 1 9.859 105 9.859 106 9.859 121 9.859 122 Integraded VPC pressure control.

RkJQdWJsaXNoZXIy MzkwNDcw