Cope-LLG Catalogue 2018

879 7. Heating and cooling technology Heating/Test incubators GENERAL CATALOGUE EDITION 20 E & OE. Constant Climate Chambers HPP Memmert Specifications Working-temperature range HPP110 - 1060 without light, without humidity: 0 (max. 25 °C below ambient) to +70 °C without light, with humidity: +5 °C (at least 20 °C below ambient) to +70 °C Working-temperature range HPP110 - 750 with light, without/with humidity: +15 to +40 °C Setting temperature range HPP1400 without light, without/with humidity: +15 °C to +60 °C Setting accuracy temperature: 0.1 °C Adjustment range humidity HPP110 - 1060: without light: 10 to 80% rh HPP1400: without light: 10 to 80% rh HPP110 - 750: with light: 10 to 80% rh Setting accuracy humidity: 0.5 % rh Power supply: 230 V, 50/60 Hz; 115 V, 50/60 Hz at no extra cost 1 9.868 022 2 6.286 315 1 2 Type Capacity Housing (W x D x H) Internal dimensions (W x D x H) Rating Shelf support ribs/shelves Weight PK Cat. No. l mm mm W kg HPP110 HPP260 HPP400 HPP750 HPP1060 HPP1400 108 256 384 749 1060 1360 745 x 674** x 864 824 x 774** x 1183 824 x 788**x 1720 1224 x 874** x 1726 1224 x 1139** x 1661 1435 x 1055** x 1968 560 x 400* x 480 640 x 500* x 800 640 x 500* x 1200 1040 x 600* x 1200 1040 x 850* x 1200 1250 x 750* x 1450 650 820 1200 1200 1500 3100 5/2 9/2 14/2 14/2 14/2 28/4 77 122 160 208 260 450 1 1 1 1 1 1 9.868 021 9.868 022 6.272 234 9.868 023 6.272 235 6.286 315 * Minus 10 mm for fan **Depth without door handle, please add 56mm The constant climate chamber generation with the unique ControlCOCKPIT for a quick and intuitive operation. Perfectly suited for stability tests, storage in controlled environment and conditioning. Energy efficient and maintenance free. Standard equipment: - PID microprocessor control with integrated auto-diagnostic system - Interior stainless steel 1.4301 (ASTM 304),deep-drawn - Structured stainless steel housing, scratch-resistant, robust and durable; rear of zinc-plated steel - High-temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standards - Internal data logger with a storage capacity of at least 10 years - German, English, French, Spanish language settings available on the ControlCOCKPIT - Digital backwards counter with target time setting adjustable between 1 minute and 99 days - The SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamber. - Adjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT, for example relative humidity - mounted on lockable castors - TwinDISPLAY: ControlCOCKPIT with two TFT displays - For a detailed description please see Peltier cooled incubators IPPplus

RkJQdWJsaXNoZXIy MzkwNDcw