Cope-LLG Catalogue 2018

951 8. Liquid Handling Pipettes/Microlitre pipettes GENERAL CATALOGUE EDITION 20 E & OE. Electronic multichannel microliter pipettes Eppendorf Xplorer ® plus, variable The electronic pipettes Eppendorf Xplorer plus were specially designed for high professional standards to provide optimal support for you in your work, with a new intuitive operating concept and design based on the proven Eppendorf PhysioCare ® Concept. - Autodispense - Manual pipetting, multi-aspirate,dilution, sequential pipetting, sequential dispensing, reverse pipetting - Programming of multiple modes in a sequence - Setting of fixed volumes - Password protection - History function - Service interval warning 1 Eppendorf AG Capacity Increments Accuracy max. vol. Precision max. vol. Channels Control button PK Cat. No. µl µl ( ≤ ± R%) ( ≤ CV%) colour 0.5 - 10 5 - 100 15 - 300 50 - 1200 0.5 - 10 5 - 100 15 - 300 50 - 1200 0.01 0.1 0.2 1.0 0.01 0.1 0.2 1.0 2.0 0.8 0.6 1.2 2.0 0.8 0.6 1.2 0.8 0.25 0.25 0.3 0.8 0.25 0.25 0.3 8 8 8 8 12 12 12 12 medium grey yellow orange green medium grey yellow orange green 1 1 1 1 1 1 1 1 9.283 187 9.283 189 9.283 191 9.283 193 9.283 188 9.283 190 9.283 192 9.283 194 1 Pipette Leak Testing Unit (PLT unit) Improved process reliability with functional validation of air-displacement pipettes. The most frequent cause of inaccuracy in piston-operated pipettes is leakage. This arises from damage either to the seals, pistons or tip cones. Often not detectable by the naked eye, leaks lead to significant volume errors. The BRAND pipette leak tester (PLT unit) for air displacement pipettes finds even the smallest leaks within seconds. - Limit values for the commercially available single- and multichannel pipettes in the volume range 1µl to 10ml are pre- programmed. - Testing with and without tips - Test results in seconds - Patent pending According to monitoring of measuring instruments, air-displacement pipettes must be checked at regular intervals and the results must be compared with the ISO 8655-2 error limits. However, a calibration certificate only reflects the results at the time of testing. The time between these calibrations is crucial, since leaks can occur at any time. Well over 80% of pipettes sent in for repair have leaks and are outside their volume tolerances, even if they don't drip. While the PLT unit cannot replace regular gravimetric testing, daily pipette checks can provide a safeguard during the periods between calibrations. Even the smallest leaks are detected. Process reliability for the pipettes is thus significantly improved. Items supplied: PLT unit (Pipette Leak Testing Unit) including one adapter each for testing air-displacement pipettes with tip (mounted) and without tip, 2 plugs, 3 replacement PE filters for the pipette adapters, universal AC adapter, quality certificate and operating manual. 2 BRAND Type PK Cat. No. Pipette Leak Testing Unit 1 4.007 886 2 Accessories for Pipette Leak Testing Unit (PLT unit) BRAND Description PK Cat. No. 1-channel pipette adapter, for testing with tip, incl. 1 blind plug 1-channel pipette adapter, for testing without tip, incl. 1 blind plug 4-channel pipette adapter, for testing with and without tip, incl. 4 blind plugs Filters, PE, for pipette adapter Software PLT connect for PLT unit to simplify the documentation of leak tests performed Universal AC adapter, Input: AC 100 V - 240 V, 50/60 Hz, Output: DC 6.5 V, 800 mA 1 1 1 10 1 1 9.280 575 9.280 576 9.280 577 9.280 578 6.280 984 9.280 579

RkJQdWJsaXNoZXIy MzkwNDcw