Cope-LLG Catalogue 2018

1466 14. Chromatography Gas chromatography/GC columns GENERAL CATALOGUE EDITION 20 E & OE. OPTIMA ® 5 capillary columns for GC 5 % phenyl - 95 % dimethylpolysiloxane USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond ® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32 mm ID and films <3 µm the max. temperature for isothermal operation is 340 °C, the max. temperature for short isotherms in a temperature programme is 360 °C for 0.53mm ID columns with films < 3 µm the max. temperatures are 320 and 340 °C, resp. for thick film columns with films ≥ 3 µm the max. temperatures are 300 and 320°C, resp. Further lengths available on request. 1 MACHEREY-NAGEL Int. diam. Ext. diam. Length Film thickness PK Cat. No. mm mm m µm 0.10 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.53 0.53 0.53 0.53 0.53 0.53 0.53 0.53 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 10 25 25 25 25 25 30 30 30 30 30 25 25 25 25 25 25 25 30 30 30 30 30 30 30 25 25 25 25 30 30 30 30 0.10 0.10 0.25 0.35 0.50 1.00 0.10 0.25 0.35 0.50 1.00 0.10 0.25 0.35 0.50 1.00 3.00 5.00 0.10 0.25 0.35 0.50 1.00 3.00 5.00 0.50 1.00 2.00 5.00 0.50 1.00 2.00 5.00 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4.003 235 9.003 709 9.003 715 9.003 719 9.003 723 9.003 727 9.003 710 9.003 716 9.003 720 9.003 724 9.003 728 9.003 733 9.003 738 9.003 742 9.003 746 9.003 751 9.003 755 9.003 760 9.003 734 9.003 739 9.003 743 9.003 747 9.003 752 9.003 756 9.003 761 4.003 155 4.003 168 4.003 158 4.003 261 4.003 156 4.003 169 4.003 159 4.003 262 Custom-made columns to your specifications available on request. Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen. Additionally, we supply the corresponding test mixture with each column. 1 OPTIMA ® 5 MS capillary columns for GC 5 % diphenyl - 95 % dimethylpolysiloxane nonpolar phase with low bleeding, deal for GC/MS and ECD applications and general analyses at trace level perfect inertness for basic compounds. Similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS. max. temperature for isothermal operation: 340 °C, max. temperature for short isotherms in a temperature programme: 360 °C 2 MACHEREY-NAGEL Int. diam. Ext. diam. Length Film thickness PK Cat. No. mm mm m µm 0.25 0.25 0.25 0.32 0.32 0.4 0.4 0.4 0.5 0.5 30 30 30 30 30 0.25 0.50 1.00 0.25 0.50 1 1 1 1 1 7.080 092 4.003 099 4.003 101 6.700 690 4.003 093 Custom-made columns to your specifications available on request. Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen. Additionally, we supply the corresponding test mixture with each column. 2 Other GC-columns on request.

RkJQdWJsaXNoZXIy MzkwNDcw